Arq. odontol ; 59: 106-113, 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1518971

ABSTRACT

Aim: The purpose of this study was to evaluate the efficacy to determine the root canal length, in vitro,of both the electronic apex locator (M2) and the autostop (AS - M3) functions of the Endus Duo Gnatus endodontic motor (Gnatus, São Paulo, SP, Brazil). Methods: Thirty extracted human single-rooted premolars had their root canal lengths (TLs) up to the apical foramen determined using the Endus Duo Gnatus in two ways: (1) In the stainless steel (SS) control group, the measurement was obtained using a stainless steel hand instrument with the electronic locator mode (M2 function) connected to a stainless-steel hand instrument (K-file #15). In the NiTi rotary instrument (NiTi RI) intervention group, the measurement was obtained during the instrumentation (M3 function) of the root canals with a nickel-titanium rotary instrument (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, USA), size 25/.06. The NiTi manually used instrument (NiTi MUI) Intervention group performed the measurement in locator mode using a Hyflex instrument, placed to true length manually. Statistical analysis was performed using ANOVA followed by the Tukey post-hoc test with a significance level of p < 0.05. Results: The true mean length and standard deviation (SD) of the standardized root canals were 18.40 ± 2.14mm, while the mean lengths and standard deviations (SD) were 18.29 ± 1.89mm, 18.22 ± 1.85mm, and 17.24 ± 2.09mm for the SS, NiTi RI, and NiTi MUI groups, respectively. However, data from the NiTi MUI Intervention group indicated shorter root canal lengths when compared to the SS control group and the NiTi RI Intervention group values, and were significantly shorter than the true canal length (p < 0.001). Conclusions:The use of the motor in NiTi RI Intervention group showed acceptable results. However, the NiTi MUI Intervention group resulted in unacceptable short measurements.


Objetivo: O objetivo deste estudo foi avaliar a eficácia na determinação do comprimento do canal radicular, in vitro, das funções localizador eletrônico foraminal (M2) e auto-parada durante a instrumentação (M3) do motor endodôntico Endus Duo Gnatus ( Gnatus, São Paulo, SP, Brasil). Métodos: Trinta pré-molares humanos uniradiculares extraídos tiveram seus comprimentos de canais radiculares (CRTs) até o forame apical determinados usando o Endus Duo Gnatus de duas maneiras: (1) No grupo controle de aço inoxidável (SS), a medida foi obtida usando um instrumento manual de aço inoxidável com modo de localização eletrônica foraminal (função M2) conectado a um instrumento manual de aço inoxidável (lima tipo K #15). No grupo intervenção instrumento rotatório NiTi (NiTi RI), a medida foi obtida durante a instrumentação (função M3) dos canais radiculares com instrumento rotatório de níquel-titânio (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, EUA), tamanho 25/.06. O grupo de intervenção NiTi instrumento usado manualmente (NiTi MUI) realizou a medição no modo localizador foraminal usando um instrumento Hyflex, colocado manualmente no comprimento real do dente. A análise estatística foi realizada por meio de ANOVA seguida do teste post-hoc de Tukey com nível de significância de p < 0,05. Resultados: Os comprimentos reais médios dos dentes e desvios-padrão (DP) dos canais radiculares padronizados foram 18,40 ± 2,14 mm, enquanto os comprimentos médios e desvios- padrão (DP) foram 18,29 ± 1,89 mm, 18,22 ± 1,85 mm e 17,24 ± 2,09 mm para os grupos SS, NiTi RI e NiTi MUI, respectivamente. No entanto, os dados do grupo de intervenção NiTi MUI indicaram comprimentos de canais radiculares mais curtos quando comparados aos valores do grupo controle SS e do grupo de intervenção NiTi RI, e foram significativamente mais curtos que o comprimento real do canal (p < 0,001). Conclusões: A utilização do motor no grupo Intervenção NiTi RI apresentou resultados aceitáveis. No entanto, o grupo de intervenção NiTi MUI resultou em medições curtas inaceitáveis.


Subject(s)
Weights and Measures , Dental Equipment , Dental Pulp Cavity , Endodontics
2.
J. appl. oral sci ; 26: e20180144, 2018. graf
Article in English | LILACS, BBO | ID: biblio-954493

ABSTRACT

Abstract Objective The aim of this study was to evaluate the influence of torsional preloading on the cyclic flexural fatigue resistance of thermally treated NiTi instruments. Material and Methods Ten new instruments New Hyflex CM (HF 30.06; Coltene/Whaladent Inc.), Typhoon CM (TYP 30.06; Clinician's Choice Dental Products) and Vortex Blue (VB 30.06; Dentsply Tulsa Dental) were chosen, based on geometry and specific characteristics of the manufacturing process. The new instruments of each system were tested in a bench device to determine their fatigue resistance through mean value of number of cycles to failure (Nf) (Control Group - CG). Another group of 10 new HF, TYP and VB instruments were submitted to 20 cycles of torsional straining between 0° and 180° (Experimental Group - EG) and then submitted to fatigue until rupture under the same conditions of the CG. Tested instruments were examined by scanning electron microscopy (SEM). Data were analyzed using one-way analysis of variance and post hoc Tukey's test (α=.05). Results Higher fatigue resistance was accomplished by HF instruments, followed by VB and TYP (p<0.05). During the torsional preloading, the lowest mean torque value was observed for TYP instruments (p<0.05). The torsional preload caused a significant reduction in the Nf values (p<0.05) of about 20%, 39% and 45% for instruments HF, VB and TYP, respectively. Longitudinal cracks, generated during the torsional preloading, were present in VB files, but were not observed in the CM instruments (HF and TYP). Conclusions In conclusion, the flexural fatigue resistance of thermally treated instruments is diminished after cyclic torsional loading.


Subject(s)
Titanium/chemistry , Dental Instruments/standards , Equipment Design/methods , Equipment Failure , Torsion, Mechanical , Nickel/chemistry , Reference Values , Rotation , Stress, Mechanical , Surface Properties , Temperature , Time Factors , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Pliability , Root Canal Preparation/instrumentation
3.
J. appl. oral sci ; 24(4): 310-316, July-Aug. 2016. graf
Article in English | LILACS, BBO | ID: lil-792591

ABSTRACT

ABSTRACT Torsional overload is a fracture representative parameter for instruments in single-file techniques. Objective The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. Material and Methods Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. Results WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. Conclusion After clinical use, no statistically significant reduction in the torsional resistance was observed.


Subject(s)
Root Canal Preparation/instrumentation , Dental Instruments , Torsion, Mechanical , Reference Values , Rotation , Stress, Mechanical , Surface Properties , Titanium , Materials Testing , Microscopy, Electron, Scanning , Torque , Equipment Design , Equipment Failure , Nickel
4.
Belo Horizonte; s.n; 2013. 82 p. ilus, tab.
Thesis in English, Portuguese | LILACS, BBO | ID: lil-698319

ABSTRACT

O objetivo deste trabalho foi comparar as propriedades químicas, físicas e mecânicas de fios de níquel-titânio convencionais (CW) e termomecanicamente tratados (MW), utilizados na fabricação de instrumentos endodônticos por dois fornecedores diferentes (Dentsply Tulsa Dental Specialities, Tulsa - OK, USA e dentsply maillefer - Ballaigues, Switzerland). Foram ainda avaliados o torque e a força apical requerida pelos novos instrumentos endodônticos ProTaper NextÕ. A composição química foi determinada por espectroscopia de energia dispersiva de raios-X, a constituição de fase por difratometria de raio-X e as temperaturas de transformação por calorimetria exploratória diferencial. Ensaios de tração em carga e descarga e até ruptura, flexão em três pontos, flexão rotativa/fadiga e medidas de microdureza Vickers foram realizados para avaliar o comportamento mecânico dos fios. As superfícies de fratura foram observadas por microscopia eletrônica de varredura e as microestruturas não deformadas por microscopia eletrônica de transmissão...


Subject(s)
Dental Instruments , Root Canal Preparation/instrumentation , Torque , Root Canal Therapy/instrumentation , Spectrum Analysis , Tooth Apex/chemistry , Microscopy, Electron, Scanning , Nickel/therapeutic use , Chemical Phenomena , Titanium/therapeutic use
5.
Braz. dent. j ; 23(4): 351-356, 2012. ilus, tab
Article in English | LILACS | ID: lil-658009

ABSTRACT

This study evaluated the protocols of sonic and vacuum irrigation regarding the capacity of debris removal from root canal systems. Canal preparations were carried out on 30 mandibular first molars using the ProTaper Universal System. Teeth were divided into two experimental groups (n=15): Group 1: sonic irrigation and Group 2: vacuum irrigation protocol. Subsequently, the mesial roots were sectioned and observed by stereomicroscopy and scanning electron microscopy. Three independent examiners evaluated images of the apical thirds according to the following scores: 1= small presence of debris, 2= moderate presence of debris, and 3= dense presence of debris. Data were analyzed with ANOVA and Kruskal-Wallis tests (α=0.05). Comparison among the groups revealed that at the apical third, the root halves of Group 1 had significantly less surface debris (p=0.002) than those of Group 2. However, at 2 mm from the working length, Group 2's specimens showed less remaining debris in approximately 75% of the analyzed root canals. At the whole apical third, the sonic irrigation protocol removed significantly more debris than the vacuum protocol. However, in the region at 2 mm from the working length, the second irrigation method demonstrated a better performance.


Este estudo avaliou protocolos de irrigação sônica e a vácuo em relação à capacidade de remoção de debris do sistema de canais radiculares. Trinta primeiros molares mandibulares tiveram seus canais radiculares preparados pela utilização do Sistema ProTaper Universal. Os dentes foram divididos em dois grupos experimentais (n=15): Grupo 1: protocolo de irrigação sônica, e Grupo 2: protocolo de irrigação a vácuo. Posteriormente, as raízes mesiais foram seccionadas e observadas em lupa estereoscópica e microscopia eletrônica de varredura. Três examinadores independentes avaliaram as imagens do terço apical de acordo com as seguintes pontuações: 1. pequena presença de debris; 2: moderada presença de debris; e 3. densa presença de debris. Os dados foram analisados pelos testes estatísticos ANOVA e Kruskal-Wallis (α=0,05). A comparação entre os grupos revelou que, no terço apical, as hemissecções radiculares do Grupo 1 apresentaram debris remanescentes de forma significativamente menor (p=0,002) do que as do Grupo 2. No entanto, a 2 mm do comprimento de trabalho, as amostras do Grupo 2 mostraram menos debris remanescentes em aproximadamente 75% dos canais radiculares analisados. Considerando todo o terço apical, o protocolo de irrigação sônica removeu significativamente mais debris do que o protocolo de irrigação a vácuo. No entanto, na região a 2 mm do comprimento de trabalho, o segundo método de irrigação demonstrou um melhor desempenho.


Subject(s)
Humans , Dental Pulp Cavity/ultrastructure , Root Canal Irrigants/therapeutic use , Root Canal Preparation/methods , Tooth Apex/ultrastructure , Dentin/ultrastructure , Edetic Acid/administration & dosage , Edetic Acid/therapeutic use , Image Processing, Computer-Assisted/methods , Microscopy , Microscopy, Electron, Scanning , Root Canal Irrigants/administration & dosage , Root Canal Preparation/instrumentation , Smear Layer , Sodium Chloride , Sodium Hypochlorite/administration & dosage , Sodium Hypochlorite/therapeutic use , Sonication/instrumentation , Sonication/methods , Therapeutic Irrigation/instrumentation , Therapeutic Irrigation/methods , Vacuum
SELECTION OF CITATIONS
SEARCH DETAIL